Ask a question about this product

The MX 62 provides a redundant system to ensure an accurate analysis from the sensors. The MX 62 monitor has incorporated these new requirements and other future needs. Through its modularity, flexibility, installation and reduced operational costs, the MX 62 is an attractive solution for all gas and flame detection needs.

The MX 62 system meets the requirements of ATEX 100 A and offers the high level of security required by SK2 and SIL3 rated systems.


A secure installation for optimized costs
      

An entirely secure installation
      • The structure of the MX 62 system has been developed to provide dual measurement. Reliable data is passed quickly from
         the detectors to the relays.
     

A structured programming
      • The ConfigPro.exe software configures the MX 62 via a PC.
      • Access to the different functions is protected by several passwords.
 

Space saving and easy access
     

An optimized cost
      • The innovative design meets the new requirements in terms of security and safety
      • The modularity allows a personalized operation and reduces wiring costs
      • The flexibility helps integration of your system
      • The reliability ensures minimum maintenance
      • Programmable outputs reduce relay requirements


VARIOUS MODULES


      LED Module (A)
      16 channels (8 channels Is standard)
      • 4 alarm thresholds
      • Reset/acknowledge
      • Power “on”
      • Fault

      LCD Module (B)
      Up to 30 displays can be networked with the MX 62, allowing measurement display wherever you require.
      • Graphic, alphanumeric, high definition LCD
      • User-friendly display graphics
      • Data storage: at least 5 days (option)
      • Can be remote via RS 485

      Printer Module (C)

      • Printing alarms, relay operating status, fault, min/max average over 8 hours
      • Type ASCII, alphanumeric 40 or 80 characters
      • Parallel connection

      CPU Module (D)
      The CPU module is the heart of the system. Its backup power supply and two processors secure the MX 62 management.
      Plug in the LED and LCD modules, or remote connection via RS485 (4 wires + shield).
      • Centralized management
      • Connection to different modules
      • Connection to an internal or external printer

      Analog input Module (E)
      Analog signals from the detectors to be input into the control system. Dual converters ensure reliable and redundant
      operation.
      • Direct connection with the MX 62 system or remote via the adapter module
      • Up to 8 measurement points, 2 or 3 wire

      Adapter Module (F)
      • Allows 3 operating modes :
         - Up to 16 addressable detectors in a loop configuration
         - Up to 8 addressable detectors combined with a remote analog module
         - Connection of 2 analog input modules
      • The module can be remote via 2 RS485 networks (2 x 4 wires + screened system)

      Relay Module (G)

      • Fitted with 2 processors linked with the CPU
         - Principal module: 8 relays
         - Extension module: 8 relays
         - NO/NC contacts
         - Breaking capacity: 460 VA, 60 W
         - Positive safety individually programmable
       • The module can be remote via 2 RS485 (2 x 4 wires + screened system)

      Analog Output Module (H)

      • Fitted with 2 processors linked with the CPU
         - Fitted with 8 analog 4-20 mA or 0-10 V outputs
      • Each output is programmed to transmit:
         - The real time value for one each input
         - The linearized value
         - Means or max for a detectors group
      • Mimic module: open collector (56) suitable to drive LED mimic panel as per MX 62 channels

     
Communication Module (I)
      • Link to a supervisor for data exportation (PLC, DCS or SCADA)
      • Link with CPU via the RS 232
      • Personalized or ModBus protocol via RS 422
      • Optional communication splitter module available







more categories


Portables

Fixed

Stand - Alone

Manufacturers




Contact Us

668 Easton Ave
Somerset, NJ 08873
PH 800-452-6822
Fax 732-828-4912
sales@emlinc.com
service@emlinc.com
SERVICE RETURN FORM
Adobe Acrobat .pdf
Microsoft Office .doc
Register Here For Product News and Updates!
Registration is also needed for online purchases.
(Coming Soon!) Smile
PRIVACY POLICY:
We do not sell, rent or disclose your personal information to anyone! EVER!!!

SAFETY ADVISORIES

Products at a glance...

SURVIVAIR Opti-Fit APR-FULL FACE
SURVIVAIR Opti-Fit APR-FULL FACE
Biosystems PhD 5
Biosystems PhD 5
First Responder
First Responder
GfG 4100 DP Control Panel
GfG 4100 DP Control Panel
CEX300
CEX300
T.ex
T.ex
GfG GMA 40B Series
GfG GMA 40B Series
DuraFlex Ultra Harness
DuraFlex Ultra Harness
Biosystems PhD Lite
Biosystems PhD Lite
Howard Leight QM24+
Howard Leight QM24+
Crowcon Gasman
Crowcon Gasman
Oldham MX32
Oldham MX32
SURVIVAIR PREMIER S SERIES
SURVIVAIR PREMIER S SERIES
Crowcon Xsafe
Crowcon Xsafe
FI 2000
FI 2000
OLCT80
OLCT80
GfG GMA 300
GfG GMA 300
First Responder
First Responder

WINTER SPECIALS!!!

MX4 iQuad (15% OFF!)
MX4 iQuad (15% OFF!)
Call for Pricing
GfG G450 (15% OFF!!)
GfG G450 (15% OFF!!)
Call for Pricing
BW Gas Alert Max XT (15% OFF!)
BW Gas Alert Max XT (15% OFF!)
Call for Pricing
V!SA (SPECIAL PRICING)
V!SA (SPECIAL PRICING)
Call for Pricing

Customer Poll

How often does your company calibrate its gas monitors?
 

OSHA Bulletin

OSHA bulletin on Calibration Frequency. Registration Required.

Login/Register






Who's Online

We have 37 guests online

Employee Portal

Webmail Access

Copyright © 2010 Electronic Measurement Labs Inc.. All Rights Reserved. Designed by JoomlArt.com.