Madur GA21 Bio+
View Full-Size Image


Madur GA21 Bio+

Price per Unit (piece): Call for Pricing

Ask a question about this product

The gas analyser GA-21Bio plus  is designed for use in waste plants where it is necessary to measure the gases produced and the emissions from a connected power or heat generation station. This is now possible with a single instrument thanks to the use of the most modern technology. Like all our instruments, the GA-21Bio plus is manufactured to give a long working life.
Using the optional dryer it is possible to carry out longer term measurements. Three extra analogue inputs allow the simultaneous measurement of a voltage or current signal and a temperature. This makes it ideally suited for measurements on district heating plants. Manufactured with EN50379 in mind.
  • Measurement of gas concentrations
    • Gas concentrations measured with NDIR sensors: CO2, CH4
    • Gas concentrations measured with electrochemical sensors: O2, CO
    • Toxic gas concentrations measured with electrochemical sensors: CO, NO, NO2, SO2, H2S. Please ask for quote for other gases.
  • Measurement of other parameters
    • Measurement of gas and ambient temperatures
    • Pressure, draft and differential pressure measurements with 1 Pa resolution
    • Soot test according to Bacharach with a pump flow of 1.62 l/min
    • Three analogue inputs (1 current/voltage, 1 thermocouple, 1 thermistor)
  • Calculation
    • Calculation of absolute and relative mass concentrations & relative emissions
    • Calculation of all relevant combustion parameters
  • Processing and presentation of measured data
    • All results shown on display
    • Averaging of all measured values. Averaging time: 10 sec - 60min
    • Graphical presentation of all measured values as diagram (option)
    • Memory capacity for 1024 sets of data, organised into 10 data banks
    • Up to 9 separate items in a data set
    • User definition of the 9 items
    • Memory capacity for 30 reports
    • Data logger function for the analogue inputs
    • All measured values, stored values or displays can be printed on the internal printer.
    • Powerful PC program for analyser settings and data communication
  • Software-Eigenschaften
    • International compatibility (language, date format etc.)
    • Password protection for settings
    • Automatic zeroing when the analyser is switched on
    • Calibration of O2/CO2 during use
    • All parameters programmable
    • List of 22 common fuels
    • 10 further freely programmable fuels
    • Permanent automatic check of the instrument with acoustic warning and full information in the "control list"
    • Compensation of cross sensitivity and temperature drift of gas sensors
  • Hardware capabilities
    • Electronic regulation of the pump flow rate
    • Integrated clock/calendar
    • Internal 57 mm dot-matrix printer
    • Power from rechargeable battery or mains
    • Big (70 x 60 mm) LCD display with backlighting (Graphics or 11 x 21 characters)
    • Gas probe with thermocouple and condensate trap
    • Power for heated probe holder during mains operation
    • RS-232C interface and multifunctional PC program






more categories


Portables

Fixed

Stand - Alone

Manufacturers




Contact Us

668 Easton Ave
Somerset, NJ 08873
PH 800-452-6822
Fax 732-828-4912
sales@emlinc.com
service@emlinc.com
SERVICE RETURN FORM
Adobe Acrobat .pdf
Microsoft Office .doc
Register Here For Product News and Updates!
Registration is also needed for online purchases.
(Coming Soon!) Smile
PRIVACY POLICY:
We do not sell, rent or disclose your personal information to anyone! EVER!!!

SAFETY ADVISORIES

Products at a glance...

Howard Leight Clarity
Howard Leight Clarity
iTrans
iTrans
3M 450
3M 450
Biosystems ToxiVision EX
Biosystems ToxiVision EX
SURVIVAIR ONE-Fit NBW95V
SURVIVAIR ONE-Fit NBW95V
Octigas
Octigas
FI 2000
FI 2000
Biosystems PosiChek3
Biosystems PosiChek3
Madur GA21 Bio+
Madur GA21 Bio+
Crowcon TXgard Plus
Crowcon TXgard Plus
Biosystems ToxiPro
Biosystems ToxiPro
BW Gas Alert Micro 5
BW Gas Alert Micro 5
Carbon Dioxide Detection
Carbon Dioxide Detection
MX52
MX52
Oxygas 500
Oxygas 500
Gassurveyor 400 Series
Gassurveyor 400 Series
3M 450
3M 450
iTX
iTX

WINTER SPECIALS!!!

V!SA (SPECIAL PRICING)
V!SA (SPECIAL PRICING)
Call for Pricing
GfG G450 (15% OFF!!)
GfG G450 (15% OFF!!)
Call for Pricing
MX4 iQuad (15% OFF!)
MX4 iQuad (15% OFF!)
Call for Pricing
BW Gas Alert Max XT (15% OFF!)
BW Gas Alert Max XT (15% OFF!)
Call for Pricing

Customer Poll

How often does your company calibrate its gas monitors?
 

OSHA Bulletin

OSHA bulletin on Calibration Frequency. Registration Required.

Login/Register






Who's Online

We have 21 guests online

Employee Portal

Webmail Access

Copyright © 2010 Electronic Measurement Labs Inc.. All Rights Reserved. Designed by JoomlArt.com.